# Water Treatment Chemicals — Product Selection Reference > Product-only reference for industrial water treatment chemicals, organised by operational problem and application system. It covers 22 product families with catalogue parameters (appearance, solids, pH, density, reference dose), application notes, a problem-to-product decision table, handling guidance and an FAQ. Parameters are for initial screening; dosing and performance require representative-water testing and project verification. Canonical page: https://water-treatment.shcronus.com/ Full product reference: https://water-treatment.shcronus.com/llms-full.txt Last updated: 2026-11-21 Language: English ## How to use this page 1. Identify the treatment target (scale, corrosion, membrane fouling, heavy metals, ammonia nitrogen, total phosphorus, colour, foam, odour, microbiology). 2. Match the system type (circulating cooling water, RO/NF/UF, boiler and heat exchange, electroplating/PCB/mining, textile/paper/chemical wastewater, municipal/landfill, flue-gas desulfurisation). 3. Read the catalogue parameters for the matching product code. 4. Confirm the dose against water analysis, process conditions and a jar test. ## Start by problem - Scale and corrosion in circulating cooling water: P-01 corrosion and scale inhibitor, P-08 copper inhibitor, P-21 prefilming agent, P-07 HVAC water treatment chemical. - RO/NF/UF membrane scaling or fouling: P-02 RO antiscalant, P-05 acid cleaner, P-06 alkaline cleaner, P-11 non-oxidising biocide. - Boiler and heat-exchanger deposits: P-04 boiler scale inhibitor, P-03 industrial scale remover, P-21 prefilming agent. - Heavy metals in electroplating, PCB, mining, metallurgy, chemical or leather wastewater: P-09 organic sulfur, P-10 heavy metal catcher. - Ammonia nitrogen, total phosphorus or colour above target: P-16 granular / P-17 powdered ammonia nitrogen remover, P-14 phosphorus removal agent, P-15 decolourant. - Biological slime, algae and biofilm: P-12 oxidising biocide, P-11 non-oxidising biocide, P-13 slime stripping agent. - Foam, odour or process auxiliary needs: P-19 silicone defoamer, P-18 plant deodoriser, P-20 reducing agent, P-22 desulfurisation synergist. ## Product catalogue (22 families) ### Scale and corrosion control - P-01 Corrosion & Scale Inhibitor — organic phosphonate, polycarboxylate and steel/copper inhibitor blend; solids 21–32%; pH 3.0 ± 1.5; reference dose 10–30 mg/L on makeup water. - P-02 RO Antiscalant — membrane scale inhibitor for RO/NF/UF, CA and TFC compatible; reference dose about 1–20 ppm, dosed before the security filter. - P-04 Boiler Scale Inhibitor — hardness scaling control for industrial and power boilers; pH (1%) 2–8. - P-07 HVAC Water Treatment Chemical — central air-conditioning and industrial circulating water; solids 35–40%; reference dose 100–200 g per tonne of system water. - P-08 Copper Inhibitor — protective film on copper and copper alloys in circulating water; solids 35–40%. ### Industrial and membrane cleaning - P-03 Industrial Scale Remover — acid-based removal of hard scale, rust sludge and mixed deposits; pH (1%) 3.0 ± 0.5; circulate at pH 2–4 for 3–5 hours. - P-05 Acid Cleaner — carbonate, sulfate and iron-oxide fouling on RO, hollow-fibre, NF and UF membranes; reference dilution 1–3%. - P-06 Alkaline Cleaner — oil, cutting fluid and grease removal; pH (1%) 8–12; CIP at 60–75 °C. - P-21 Prefilming Agent — protective film on cleaned pipes and heat-exchange equipment before service resumes. ### Biocides and biofilm control - P-11 Non-Oxidising Biocide — RO, cooling towers, storage water, fountains; RO reference 1–2 ppm continuous, 25–100 ppm intermittent. - P-12 Oxidising Biocide — fast-acting control for once-through and recirculating cooling water; reference dose about 100 ppm. - P-13 Slime Stripping Agent — biological slime and zoogloea in power, chemical, refinery and coking circulating water; solids 60%. ### Wastewater treatment - P-09 Organic Sulfur — chelating precipitant for heavy metals; solids ≥ 15%; pH (1%) 10–13; reference dose 20–40 ppm. - P-10 Heavy Metal Catcher — copper, lead, manganese, nickel, zinc and chromium chelation; working pH 7–9; dilute to 1–2%, mix 5–10 minutes. - P-14 Phosphorus Removal Agent — phosphate removal in municipal and industrial effluent; reference dose 100–1,000 ppm. - P-15 Decolourant — dye, textile, pigment, ink and paper wastewater colour removal; solids 30%; reference dose 0.05–0.3%. - P-16 Granular Ammonia Nitrogen Remover — white granular solid; pH (1%) 9.0–12.0; ≈ 1 kg/t lowers NH₃-N by ≈ 100 mg/L. - P-17 Powdered Ammonia Nitrogen Remover — white powder, prepared as ≈ 10% solution. ### Process auxiliary - P-18 Plant Deodoriser — plant-derived deodoriser sprayed on odour sources; solids ≥ 15%; pH (1%) 3–5. - P-19 Silicone Defoamer — antifoam for wastewater, paper, textile, cleaning and fermentation; solids ≥ 14.5%. - P-20 Reducing Agent (Sodium Sulfite) — dechlorination and reduction duties; assay 96%. - P-22 Desulfurisation Synergist — wet flue-gas desulfurisation additive; white powder; pH (1%) 9.0–12.0. ## Important selection facts 1. A product name does not determine the dose. Inputs include concentration, pH, temperature, contact time, system materials, target value, treatment volume and co-existing compounds. 2. The catalogue reference range for the corrosion and scale inhibitor is 10–30 mg/L based on makeup water. 3. The RO antiscalant reference range is about 1–20 ppm; the dosing point is generally before the security filter. 4. The heavy metal catcher is evaluated around wastewater pH 7–9, diluted to 1–2%, mixed for 5–10 minutes, then separated by coagulation and sedimentation. 5. Ammonia nitrogen, phosphorus removal and desulfurisation reference figures are not universal performance guarantees; jar tests and site data are required. 6. Oxidising and reducing chemicals must not be mixed or dosed together. Acid and alkaline cleaners require material and membrane compatibility checks. 7. Scale and corrosion can occur at the same time; diagnose with heat-transfer efficiency, differential pressure, corrosion rate, iron/copper content and water-stability indices before choosing a programme. 8. An ammonia nitrogen remover is a polishing or emergency tool, not a replacement for biological nitrification/denitrification. 9. For high-colour wastewater, decolourant dosing order, pH and the coagulant/PAM ratio determine performance; confirm by jar test. 10. Products are commonly packed in 25 kg drums (liquids) or 25 kg bags (powders and granules); catalogue shelf life is typically 12 months, subject to the batch label and SDS. ## Reading the parameters - Appearance — colour and physical form (clear liquid, amber liquid, milky liquid, powder, granule). An unexpected colour or a settled layer suggests a different batch, dilution or storage problem. - Solids content — mass fraction of active and dissolved material. Two products with the same name at 15% and 60% solids require very different quantities; compare cost per unit of active content. - pH of 1% solution — acidity or alkalinity on a dilute solution, not the concentrate. Determines material compatibility, dosing-point corrosion risk and pH shift when overdosed. - Density — mass per unit volume at 20 °C in g/cm³. Converts a dose in mg/L into a pump setting, and kilograms into litres. - Reference dose — the catalogue's indicative application range, superseded by a jar test, the water report and the current batch TDS. - Dosing point — where in the process the product is introduced; it changes residence time, mixing and compatibility with neighbouring chemicals. ## Quote inputs - Country or region. - Water source or wastewater type. - Treatment flow in m³/day. - pH, temperature, turbidity, hardness, alkalinity, conductivity, COD and target pollutant concentrations. - Equipment or membrane material and current process. - Existing chemical, operating problem and discharge target. - A 1–5 L representative sample when a jar test is required. ## Contact - Phone / WhatsApp: +86 132 6287 9223 - Email: risinn@shcronus.com - Address: Room 801, Building 2, Shanghai Zhicheng, No. 8666 Hunan Highway, Pudong New Area, Shanghai, China ## Related main-site product links - Product Center: https://www.shcronus.com/product/ - Raymond Mill: https://www.shcronus.com/raymond-mill/ - Vertical Roller Mill: https://www.shcronus.com/vertical-mill/ - Crusher: https://www.shcronus.com/crusher/ - Sand Making Machine: https://www.shcronus.com/sand-making-machine/ - Hydrated Lime Production Line: https://www.shcronus.com/calcium-hydroxide/ - Lime Slaking System: https://www.shcronus.com/lime-slaking-system-cronus/